dcm2mnc issue with GE MEDICAL SYSTEMS DISCOVERY MR750w #96

Open
cmadjar opened this issue Sep 24, 2019 · 2 comments
Open

dcm2mnc issue with GE MEDICAL SYSTEMS DISCOVERY MR750w #96

cmadjar opened this issue Sep 24, 2019 · 2 comments

Comments

@cmadjar
Copy link

cmadjar commented Sep 24, 2019

Converting datasets acquired with a GE MEDICAL SYSTEMS DISCOVERY MR750w (software 27\LX\MR Software release:DV25.1_R03_1802.a) creates empty MINC files (min and max values within all MINC files are 0).

Output from the dcm2mnc command on those datasets:
GE_dcm2mnc_output.txt

@rdvincent
Copy link
Member

Do you have a sample dataset?

@cmadjar
Copy link
Author

cmadjar commented Sep 25, 2019

Hi Bert,

I copied a sample dataset on ace-storage-2.cbrain.mcgill.ca. Path to the dataset: /data1/ACElab_Shared/cmadjar/GE_sample_dataset_for_Bert_2019-09-25.zip

Thank you!