The revision history describes the changes that were made to this document listed by revision, starting with the most recent publication.
First publication of the document.
Updated document for SmartHLS™ 2021.2 release.
Updated document for minor wordings and outdated figures.
Added Appendix C on Rebuilding the SoftConsole Project
Updated document for outdated figures, references, contents for SmartHLS™ 2022.2 release.
Updated document for outdated figures and outputs.
Updated document for SmartHLS™ 2024.1 release.
Updated document for SmartHLS™ 2024.2 release.
Time Required: 4 hours
Goals of this Training:
- Get hands-on experience designing in SmartHLS™.
- Introduce the AXI protocol and explain how to generate AXI interfaces using SmartHLS.
- Show a SmartHLS design that has processor/accelerator communication.
Training Topics:
- Wide Multiply accelerator design:
- Hands-on design with SmartHLS using fixed-point types to generate an arithmetic hardware block with a wide datapath and compare to an RTL reference design.
- Referring to previous SmartHLS trainings.
- Referring to the SmartHLS User Guide.
- Referring to the SmartHLS Github examples repository.
- AXI protocol and SmartHLS:
- SmartHLS AXI target (also called AXI subordinate or slave) interface support and integration with a soft Mi-V processor.
- SmartHLS AXI initiator (also called AXI manager or master) interface support and integration with DDR4 off-chip memory.
- AXI initiator interface support for burst reads and burst writes to/from DDR4.
- Integration into SmartDesign using CoreAXI4Interconnect.
- Mi-V processor SoftConsole code for communicating with the SmartHLS hardware block through the AXI target interface.
The main reason why FPGA engineers use high-level synthesis software is to increase their productivity. Designing hardware using C++ offers a higher level of abstraction than RTL design. Higher abstraction means less code to write, less bugs and better maintainability.
In the SmartHLS design flow (formerly LegUp HLS), the engineer implements their design in C++ software and verifies the functionality with software tests. Next, they specify a top-level C++ function, which SmartHLS will compile into an equivalent Verilog hardware module. SmartHLS can run co-simulation to verify the hardware module’s behavior matches the software. SmartHLS uses Libero® SoC to generate the post-layout timing and resource reports for the Verilog module. Finally, SmartHLS generates a SmartDesign IP component that the engineer can instantiate into their SmartDesign system in Libero SoC. Figure 11 shows the SmartHLS high-level synthesis FPGA design flow for targeting a Microchip PolarFire FPGA.
The C++ code input to the SmartHLS Synthesis tool describes the behavior of one specific hardware functional block that exists in the overall FPGA design. A hardware engineer writes the C++ in SmartHLS to describe the hardware logic, not a software engineer (who would typically write C/C++ code for a processor to execute). The hardware engineer will need to handle advanced hardware issues outside of the SmartHLS tool such as the clock network, clock domain crossing, Triple Modular Redundancy (TMR) settings, etc.
Figure 1: Smart High-level Synthesis Design Flow Targeting a PolarFire FPGA
Before beginning this training, you should install the following software:
- Libero® SoC 2024.2 (or later) with QuestaSim
- SmartHLS 2024.2 (or later): this is packaged with Libero
- A terminal emulator such as PuTTY
This document uses the Windows versions of Libero® SoC 2024.2 and SmartHLS 2024.2. Depending on the version you use, the results generated from your Libero® SoC and SmartHLS could be slightly different from that presented in this document.
Additionally, while the default simulator for SmartHLS is now QuestaSim, ModelSim will still be supported. Some screenshots of the simulator may have been captured using Modelsim.
You should download the training design files in advance:
- Github link to all SmartHLS trainings and examples:
https://github.com/MicrochipTech/fpga-hls-examples
- ZIP file: https://github.com/MicrochipTech/fpga-hls-examples/archive/refs/heads/main.zip
- We’ll use the Training3 folder for this training.
- Download
precompiled-binaries.tar.gz
from the Release Assets. This archive contains the pre-compiled bitstream required for this training. - Alternatively, you can re-generate the bitstream and Libero project from scratch by following the instructions here: https://github.com/MicrochipTech/fpga-hls-examples/tree/main/Training3/Libero
In Libero SoC 2024.2 you should download the following IPs in the IP Catalog as their configurators will be used in this training:
- Mi-V RV32 version 3.0.100
- CoreAXI4Interconnect version 2.8.103
The following hardware is required:
- PolarFire FPGA Video and Imaging Kit (MPF300-VIDEO-KIT).
- Monitor with an HDMI input.
In the SmartHLS user guide, you should read Section 'SmartHLS C/C++ Library' up to and including Section 'Supported Operations in ap_[u]int/ap_[u]fixpt, and floating-point', and Section 'AXI4 Target Interface'. This knowledge will be directly applied in this training.
We assume some knowledge of the C/C++ programming language for this training.
We will use this cursor symbol throughout this training document to indicate sections where you need to perform actions to follow along.
Generate the Libero project in advance.
- If you are using Windows, open the Windows command prompt (cmd) and navigate to the Libero directory. Then run
run_shls_on_examples.ps1
to generate the HLS example designs. e.g.:
cd C:\Workspace\fpga-hls-examples-main\Training2\Libero
./run_shls_on_examples.ps1
- If you are using Linux, open a terminal and navigate to the Libero directory. Then run
run_shls_on_examples.sh
to generate the HLS example designs. e.g.:
cd Workspace/fpga-hls-examples-main/Training3/Libero
bash run_shls_on_examples.sh
- When this completes, use Libero to generate the project. Open Libero 2024.2, and go to File -> Execute Script.
Choose
libero_flow.tcl
under "Script file". In Arguments, putGENERATE_ONLY:1
.
- Click 'Run'. This should take about 10 minutes.
In this section we will set up the workspace and projects for SmartHLS used in this tutorial, as well as tool paths. We assume that SmartHLS and Libero® SoC have already been installed prior to this training. A Libero SoC install is needed for SmartHLS to run synthesis.
-
Download the zip file from github if you have not already (see Prerequisites). Extract the contents of the zip file. We will use the Training3 folder of the extracted content for this training.
-
Open SmartHLS and choose a workspace.
You may want to select a new folder so you can have a blank workspace for this training. Warning: Make sure there are no spaces in your workspace path. Otherwise, SmartHLS will error out when running synthesis.
- Select File -> Import...
-
In the Import window, select General->Existing Projects into Workspace and then click Next.
-
In the next step, select “Select root directory” and then click Browse... In the popup window browse to the Training3 directory and click OK.
-
Now in the Projects box you should see that all SmartHLS projects have been selected. Click Finish to import the projects.
-
After importing you should see 6 projects in the Project Explorer on the left.
-
Next go to the top toolbar and select SmartHLS->Tool Path Settings.
-
Make sure the tool paths to vsim.exe and libero.exe are properly set to:
C:\Microchip\Libero_SoC_v2024.2\QuestaSim\questasim_mcoem\win64\vsim.exe
C:\Microchip\Libero_SoC_v2024.2\Designer\bin\libero.exe
Note: update these tool paths if your Libero is installed in a different location.
In this training, we will not be creating SmartHLS projects from scratch, please see the SmartHLS Sobel Tutorial for instructions on creating a fresh SmartHLS project.
In this section, we will introduce the “wide multiply” design created by one of our FAEs using RTL. The wide multiply design performs a series of arithmetic operations on five fixed-point and integer inputs. We will recreate the same wide multiply design using SmartHLS, to apply what we learned in the previous trainings. We will then go over a reference SmartHLS implementation of the wide multiply.
Goals of this section:
- Apply learning from previous trainings by designing with SmartHLS.
- Read and familiarize yourself with the SmartHLS User Guide.
- Implement and optimize a design based on requirements.
The wide multiply RTL reference design (WideMult) is designed by one of our FAEs for a real customer use case. The design’s requirements and design process can be found in this design document. The design takes 128-bit fixed point integers and 64-bit integers and performs a fixed set of arithmetic operations.
The WideMult block implements the function A + B + C * (D + 0.5 * (C * E)) where the signal types and widths are:
- A is a 128-bit signed: 1 sign bit, 63 integer bits, and 64 fractional bits.
- B is a 64-bit unsigned: 64 integer bits, and no fractional bits.
- C is a 64-bit signed: 1 sign bit, 63 integer bits, and no fractional bits.
- D is a 128-bit signed: 1 sign bit, 63 integer bits, and 64 fractional bits.
- E is a 128-bit signed: 1 sign bit, 63 integer bits, and 64 fractional bits.
- Result (dout) is a 256-bit signed: 1 sign bit, 191 integer bits, and 64 fractional bits.
Figure 2: High-Level Architecture of RTL Wide Multiply Block
Figure 2 shows the high-level architecture of the RTL block. The only requirement of this design is to meet a Fmax target of 156.25 MHz. The 128x64 and 192x64 multiply functions are parameterized and pipelined. The RTL implementation has a pipeline initiation interval of 1 and a latency of 37 cycles, meaning we can receive a new set of inputs every clock cycle and the first output will occur 37 cycles after the inputs arrive. The Shift Register blocks, comprised of uSRAMs, are used as delay elements to line up the inputs to the pipeline stages where they are used. Using uSRAM saves logic resources. Registers are used between operations to improve Fmax. The divide-by-two after the 128x64 multiply is an arithmetic right shift-by-one.
Table 1 shows the resources used by the RTL implementation.
Fabric + Interface 4LUT | Fabric + Interface DFF | uSRAM 1K | MACC 18x18 |
---|---|---|---|
1958 + 3288 (5246) | 10839 + 3288 (14127) | 34 | 80 |
In this section, we want you to implement the same design using SmartHLS. We will aim to implement a pipelined HLS design with an initiation interval of 1, with the same MACC usage and similar 4LUT, DFF, and uSRAM usage as presented in Table 1.
In SmartHLS you can find a base project in the wide_mult_template project:
This project includes the wide_mult.cpp C++ source file defining an
empty wide_mult
top-level HLS function for you to fill in. The main
function contains test cases to create a software testbench that can be
used for verification using co-simulation. The project also contains a
SystemVerilog testbench to verify your hardware implementation. The
testbench will check your implementation has generated the expected
hardware interface and has a pipeline initiation interval of 1 and a
latency of 7.
Your implementation of the wide_mult
top-level HLS function should take
around 10 lines of C++ code.
The recommended design process for this design is to implement the operations using the arbitrary precision SmartHLS C++ library due to its support for wide fixed-point values. We recommend writing the code as you would in software using arbitrary precision values and verifying your code using the test cases provided in the main function of wide_mult.cpp via co-simulation. You can then further check the correctness by using the provided SystemVerilog testbench to verify the generated hardware interface and pipeline latency. Then you can check to see if the quality of results is already acceptable before trying to optimize. You may find that SmartHLS has automatically optimized your design such that you do not need to perform further optimizations.
The constraint to set WideMultTopPf_Tb.sv
as the testbench should
already exist. You can check by opening the configuration menu
(). If it is not there, then add the testbench
file and WideMultTopPf_Tb
as the custom testbench using the method
shown in the Custom Testbench section of the SmartHLS Training 2 document
as shown in Figure 3.
Figure 3: Adding custom SystemVerilog testbench.
Many methods and libraries used in previous trainings can be applied in creating this wide multiply block. Some topics include the C++ arbitrary precision library, how top-level function interfaces map to hardware, and pipelining. Refer to the SmartHLS User Guide or previous trainings for more details on specific topics.
All of the necessary operators to implement the wide multiply operations are provided in the arbitrary precision library API. Read Section 'C++ Arbitrary Precision Data Types Library' in the SmartHLS User Guide if you have not already. This section provides information about the arbitrary precision library. Keep in mind that the operation performed in the divide-by-two operation in the original RTL is implemented as an arithmetic right shift-by-one. The “>>” operator in C++ is a logical right shift and not an arithmetic right shift. You must use an arithmetic right shift operation to handle signed division properly. See: Section 'Supported Operations in ap_[u]int/ap_[u]fixpt, and floating-point'.
When you use the SmartHLS C++ arbitrary precision library, SmartHLS automatically handles sign extension, padding, and shifting when operating on types of different sizes. For example, if a variable B that has 64 integer bits and 0 fractional bits is added with a variable q with 192 integer bits and 64 fractional bits, SmartHLS will automatically shift and pad B to correctly add it to q. A representation of this addition is shown in Figure 4.
Figure 4: Padded and Shifted Addition between q and B
Since there is wasted logic in having those extra padding bits in hardware, SmartHLS also automatically removes the padding when generating the hardware operations.
Because of the abstraction offered by the SmartHLS arbitrary precision library, the implementation of the wide multiply block should take no more than 10 short lines of C++ code.
A reference design exists in Reference A that includes analysis of performance and resource usage compared to the original RTL. We will go over this implementation once you have tried to create this design on your own.
In this section, we will talk about the AMBA AXI4 protocols, which we will use to allow the wide multiply core to communicate with the Mi-V soft processor present in the design. This is to allow the wide multiply core to accelerate this operation for the Mi-V. We recommend using an AXI4 interface for all processor to SmartHLS core communication because AXI is widely implemented, performant, and easy to use from the processor as a memory-mapped interface. AXI4 is also the interface we use in the upcoming SoC HLS flow.
The AXI specification is part of ARM AMBA, a family of micro controller buses first introduced in 1996. The first version of AXI (AXI3) was first included in AMBA 3.0, released in 2003. AMBA 4.0, released in 2010, includes the second version of AXI (AXI4).
In the past, the AMBA specifications have used the terms AXI master and AXI slave to define concepts in the AXI protocol. ARM has recently changed their terminology to be AXI manager as AXI master and AXI subordinate as AXI slave. However, we will be using the following terminology: AXI master is now called AXI initiator and AXI slave is now called AXI target.
There are three types of AXI4 interfaces:
- AXI4 (or AXI4-Full): for high-performance memory-mapped requirements.
- AXI4-Lite: for simple, low-throughput memory-mapped communication (for example, to and from control and status registers).
- AXI4-Stream: for high-speed streaming data. For example, video pixels.
In this training, we will refer to the family of protocols as the AXI4 protocols, and the high-performance version of the protocol as AXI4, AXI4-Full, or the AXI4 protocol.
In this training, we will be using the AXI4 protocol and briefly touch on AXI4-Lite. We will not be covering AXI4-Stream in this training. If you are interested in AXI4-Stream, you can find more information in AXI4-Stream section of the AMBA 4.0 specification.
Some key features of the AXI4 protocols are:
- Separate address/control and data phases.
- Support for unaligned data transfers, using byte strobes.
- Uses burst-based transactions with only the start address issued.
- Separate read and write data channels that can provide low-cost Direct Memory Access.
- Support for issuing multiple outstanding addresses.
- Support for out-of-order transaction completion.
- Permits easy addition of register stages to provide timing closure.
The AXI4 protocol is burst-based and defines the following 5 independent transaction channels: read address, read data, write address, write data, and write response.
The address channel carries control information that describes the nature of the data to be transferred. The data is transferred between initiator (master) and target (slave) using either the write data channel when transferring data from the initiator to the target, or the read data channel to transfer data from the target to the initiator. In a write transaction, the target uses the write response channel to signal the completion of the transfer to the initiator.
Figure 5: Read Channel Architecture
Figure 6: Write Channel Architecture
Figure 5 and Figure 6 show a typical read and write transaction using AXI4. AXI4 provides separate data and address connections for reads and writes, which allows simultaneous, bidirectional data transfer. Transfers are initiated by the Initiator Interface with a single address and can burst up to 256 words of data. At a hardware level, AXI4 allows a different clock for each AXI initiator-target pair. In addition, the AXI protocol allows the insertion of register slices (often called pipeline stages) to aid in timing closure.
Each type of AXI channel (read address, read data, write address, write data, write response) has its own set of VALID and READY signals that provide a two-way handshake mechanism. These AXI channels can be modeled with the FIFO interfaces that we have seen in past trainings. Both the read data channel and the write data channel also include a LAST control signal to indicate the transfer of the final data item in a burst transaction.
The read data channel carries both the read data and the read response information from the target to the initiator, and includes the data bus, that can be 8, 16, 32, 64, 128, 256, 512, or 1024 bits wide.
The write data channel carries the write data from the initiator to the target, and includes the data bus, that can be 8, 16, 32, 64, 128, 256, 512, or 1024 bits wide, and a byte lane strobe signal indicating which bytes of the data are valid. There is one write strobe bit for each byte of the write data bus, with the lower bits of the strobe signal specifying the validity of the lower bytes of the data bus. Write data channel information is always treated as buffered, so that the initiator can perform write transactions without target acknowledgement of previous write transactions. A target uses the write response channel to respond to write transactions. All write transactions require completion signaling on the write response channel. The completion is signaled only for a complete transaction, not for each data transfer in a transaction.
There may be other control signals present in each of these channels, but the ones mentioned in the preceding paragraphs are enough to understand the high-level use of the protocol.
The AXI protocol requires the following relationships to be maintained:
- A write response from the target to the initiator must always follow the last write transfer in the write transaction of which it is a part.
- Read data must always follow the address to which the data relates.
- Channel handshakes must conform to its dependencies.
Otherwise, the protocol does not define any relationship between the channels.
The AXI protocol provides response signaling for both read and write transactions.
The response codes are:
- OKAY: Normal access success. Indicates that a normal access has been successful. Can also indicate an exclusive access has failed.
- EXOKAY: Exclusive access okay. Indicates that either the read or write portion of an exclusive access has been successful.
- SLVERR: Target error. Used when the access has reached the target successfully, but the target wishes to return an error condition to the originating initiator.
- DECERR: Decode error. Generated, typically by an interconnect component, to indicate that there is no target at the transaction address.
AXI4-Lite is a protocol with a subset of AXI4’s features. The most important difference is that AXI4-Lite has less control signals and does not support burst transfers.
In this section, we present how a SmartHLS module can communicate with the Mi-V soft processor using the AXI4 protocol. We will modify the wide multiply design to create an AXI4 target enabled accelerator that can be used by the Mi-V processor to accelerate this wide multiply operation. We then show how we can use the same wide multiply accelerator to connect to DDR through an AXI4 initiator interface so that the accelerator can burst read inputs written into the DDR by the Mi-V and burst write results to DDR for the Mi-V to read.
Goals of this section:
- How to create an HLS accelerator for a processor.
- How to create AXI4 initiator and AXI4 target interfaces in SmartHLS.
- More hands-on experience designing with SmartHLS.
- How to burst read and write using an AXI4 initiator interface in SmartHLS.
Figure 7 shows the high-level hardware blocks used for the design. The blue arrows indicate AXI4 interface connections, where the arrow points from the AXI Initiator to the AXI Target. The blocks in blue are implemented in SmartHLS. We will only cover the Wide Multiply block in this training. More information on the Texture Mapper block can be found in Appendix B.
The Mi-V communicates with the host PC through a UART interface. The Mi-V processor can initiate AXI transactions to 3 targets: DDR, Wide Multiply and Texture Mapper. We connected the Mi-V processor to the two SmartHLS cores and a second AXI Interconnect using a 1-to-3 AXI Interconnect. The DDR is a target of two initiators, namely the Mi-V and the Wide Multiply, which is why we need a second interconnect. The second interconnect is a 2-to-1 AXI Interconnect connecting the Mi-V initiator interface from the first AXI Interconnect and the Wide Multiplier SmartHLS core to the DDR4 controller. The interconnects also provide clock domain crossing logic from the 50 MHz processor clock to the 100 MHz system clock, and from the 100 MHz system clock to the 200 MHz DDR clock.
Figure 7: SmartHLS Accelerator System Diagram
We can use an AXI4 interface to allow the Mi-V to communicate with a SmartHLS module and use the SmartHLS core to accelerate slow processor operations. We can easily implement an AXI4 target interface using SmartHLS. When we want to run many inputs at once, we may want to use DDR to store many inputs and run them all at once in the accelerator. To accomplish this, we can use a AXI4 initiator interface from the SmartHLS accelerator to read from and write to DDR once the processor has filled the DDR with inputs.
Note, the AXI4 interfaces generated by SmartHLS is an enhanced version of AXI4-Lite that supports burst transactions. This burst enabled AXI4-Lite interface can properly interface with both AXI4 and AXI4-Lite in most FPGA use cases.
In this section, we want you to implement an AXI target interface in SmartHLS to communicate with the Mi-V processor.
To start, you should see Section 'AXI4 Target Interface' in the SmartHLS User Guide if you haven’t already. This section includes information on how to create a AXI target interface in SmartHLS. You can also start with an example found in the SmartHLS Github examples repository. Note, these resources may refer to the AXI4 initiator as the AXI4 master and the AXI4 target as the AXI4 slave.
You can find the base project in the wide_mult_axi_target_template project imported in Section 'Setting Up SmartHLS'. This project includes a C++ source file wide_mult.cpp with the same test cases from the original SystemVerilog test bench. It also includes a header file axi4_target.h that holds an empty struct that you should populate. This struct will be used to construct a AXI4 target channel by SmartHLS. Note, SmartHLS does not support using C++ arbitrary precision types inside of an AXI4 target struct. However, C++ arbitrary precision types should still be used for the wide multiply computations. This can be achieved by assigning the simple types in the target struct to the corresponding slices of the arbitrary precision type. See: Section 'Selecting and Assigning to a Range of Bits'.
Next you will find the initiator_layout.txt file in the template project. This gives you the processor side memory map layout for communicating with the SmartHLS target. You should use the same layout between the processor and the SmartHLS target in order for the data transfer addressing to line up.
The run field found in the processor side layout is used to control the execution of the target. The run field will be set to 1 by the processor to signal to the SmartHLS core to begin computation on the inputs. When the SmartHLS core is done processing, it should set run to 0. The processor will poll run until the run value becomes 0, then read the SmartHLS outputs.
SmartHLS will automatically generate a burst enabled 64-bit AXI4-Lite target interface and the required control logic when a global variable struct is declared as an AXI target interface. Again, this burst enabled AXI4-Lite interface is enough for most applications and can work with both AXI4-Full and AXI4-Lite interfaces in most FPGA use cases.
With the addition of an AXI4 target interface, the implementation function body should be roughly 50 lines, where the majority of the code is related to reading from and writing to the AXI4 target struct.
A reference design exists in Appendix B. We will go over this implementation once you have tried to create this design on your own.
Now that we have seen an AXI4 target implementation that can communicate with the Mi-V in Appendix B, we have a working accelerator. However, in the case where we do not want to manually enter inputs, we can write pre-set argument values to DDR via a second AXI initiator interface from the Mi-V, then tell the wide multiply core to fetch the values from DDR and write the result back to DDR for the Mi-V to read. To achieve this, we need to implement an AXI initiator interface from the wide multiply core to read and write to the DDR.
This can be done using the SmartHLS AXI interface library. Using this library, we need to manually implement the AXI4 initiator interface by specifying read and write requests with our desired addresses and control signals. We also need to manually read and check response codes when we complete a write transaction. More information on the AXI4 protocol can be found in the AXI4 Protocol Primer.
Open the wide_mult_axi project and open the axi4_target.h file.
This AXI target struct is very similar to the one we have seen before,
except for two new control fields. The base_addr
field is used by the
Mi-V to pass in the DDR address information to the core. The error field
is used by the core to send back an error code in case it reads any
errors in the response from the DDR controller. This is also the exact
same struct as found in initiator_layout.txt.
struct TargetLayout {
uint32_t run;
uint32_t base_addr;
uint32_t error;
uint32_t result0;
...
uint32_t result7;
uint32_t A0;
...
uint32_t E3;
uint32_t padding;
};
Next open the wide_mult_axi.cpp source file. On line 4, we have included the AXI initiator interface library.
#include <hls/axi_interface.hpp>
On line 21, we have moved the wide multiply operation back into its own function and added a noinline pragma. This allows sharing of the wide multiply between the “single” and “burst” mode circuits.
ap_fixpt<256, 192> wide_mult(ap_fixpt<128, 64> A, ap_uint<64> B, ap_int<64> C,
ap_fixpt<128, 64> D, ap_fixpt<128, 64> E) {
#pragma HLS function noinline
// return A + B + C * (D + 0.5 * (C * E));
ap_fixpt<192, 128> m, n, o;
ap_fixpt<256, 192> p, q;
m = C * E;
n = m.ashr(1);
o = D + n;
p = C * o;
q = A + p;
return B + q;
}
Starting on line 37, we have the new top-level function for this design.
This function has an AxiInterface
object passed into it by reference.
This object in the function signature will generate a burst enabled
AXI4-Lite initiator interface in hardware. As template arguments, we
provide the address width, data bus width, and strobe width as
ap_uint
s.
void wide_mult_axi(AxiInterface<ap_uint<32>, ap_uint<32>, ap_uint<4>> &initiator) {
#pragma HLS function top
In the function body, we have repurposed the run field to also signify when the module should run in “single” or “burst” mode. When run is 0, the module is finished running or idle. When the module is run in single mode, the module runs the same operations as we have seen in Appendix B.
if (data.run == 0) // idle
return;
if (data.run == 1) { // single
A(31, 0) = data.A0;
...
E(127, 96) = data.E3;
r = wide_mult(A, B, C, D, E);
data.result0 = r(31, 0);
...
data.result7 = r(255, 224);
data.run = 0;
For any other value of run, the value is taken as the burst size and that number of runs are performed by reading and writing values to and from the DDR through the AXI initiator interface.
} else { // burst
// get data from DDR
const uint32_t BURST_SIZE = data.run;
const uint32_t NUM_INPUT_WORDS = 16;
const uint32_t NUM_OUTPUT_WORDS = 8;
const uint32_t WORD_SIZE = 4;
uint32 addr = data.base_addr;
ap_uint<2> bresp;
ap_uint<2> error = 0;
for (uint32_t i = 0; i < BURST_SIZE; i++) {
The SmartHLS core reads input from DDR by first issuing a single read
request in the read address channel by using the axi_m_read_req
function. This function takes the same address width, data bus width,
and strobe width template parameters as the initiator object it operates
on. As arguments, we provide the initiator interface object, the
starting address to read from, and the number of data words to burst
read, which corresponds to sixteen for inputs A-E. The address must be
the same type as the provided address width template parameter, and the
word size will match the data bus width template parameter. We then
increment the address by the byte size of the data read in this
transaction. We can now read the sixteen words from the read data
channel by making a call to axi_m_read_data
. We provide the same
address width and data bus width parameters and provide the initiator
interface object as an argument. This will read a single word from the
data read channel per call and return it. For the sixteen-word burst we
requested, we will call axi_m_read_data
sixteen times and store the
values in our input variables A-E.
axi_m_read_req<ap_uint<32>, ap_uint<32>, ap_uint<4>>(
initiator, addr, ap_uint<9>(NUM_INPUT_WORDS));
addr += NUM_INPUT_WORDS * WORD_SIZE;
A(31, 0) = axi_m_read_data<ap_uint<32>, ap_uint<32>>(initiator);
...
E(127, 96) = axi_m_read_data<ap_uint<32>, ap_uint<32>>(initiator);
We then run the wide multiply with inputs fetched from DDR.
r = wide_mult(A, B, C, D, E);
To write the result back into DDR, first we need to send a write request
in the write address channel. This is done by calling the
axi_m_write_req
function. Again, it takes the same address width,
data bus width, and strobe width template parameters as the initiator
object it operates on. The address and number of words to write are
provided as arguments. We then increment the address by the byte size of
the data read in this transaction. Now we write the wide multiply result
as eight 32-bit words to the write data channel by making a call to
axi_m_write_data
. As arguments, we provide the initiator interface
object, the data, the strobe signal for each byte of the data sent.
Lastly, we provide a flag signaling if the requested transaction has
ended. For burst transactions of eight words as requested, the last call
should set the flag to 1 while all others have it set to 0.
axi_m_write_req<ap_uint<32>, ap_uint<32>, ap_uint<4>>(
initiator, addr, ap_uint<9>(NUM_OUTPUT_WORDS));
addr += NUM_OUTPUT_WORDS * WORD_SIZE;
axi_m_write_data<ap_uint<32>, ap_uint<32>, ap_uint<4>>(
initiator, ap_uint<32>(r(31, 0)), ap_uint<4>(0xF), /*is_last=*/ 0);
...
axi_m_write_data<ap_uint<32>, ap_uint<32>, ap_uint<4>>(
initiator, ap_uint<32>(r(255, 224)), ap_uint<4>(0xF), /*is_last=*/ 1);
After a full write transaction, we manually collect the write response
by making a call to axi_m_write_response
and aggregate it in an error
variable.
bresp = axi_m_write_resp(initiator);
error |= bresp;
Make sure to read and write the correct number of data words or responses as specified in the read and write requests, otherwise the channel might fill, and the design will hang.
For this design, we chose the data bus width to be 32-bits to
conceptually line up with the 32-bit values written into the DDR by the
Mi-V. For ease of implementation, you can also make the data bus wider
in order to get more data per read. For example, if the data bus was
256-bits wide, you can read all inputs with two axi_m_read_data
calls
and write the output in a single axi_m_write_data
call.
Lastly, once the main loop is finished, the module writes the aggregated error code into its target memory and then sets run to 0, signaling to the Mi-V that it can read the results back from the DDR.
// Send aggregate response code back to MiV
data.error = error;
// Signal accelerator finished
data.run = 0;
In order to simulate the design in co-simulation, the operations of an AXI4 target must be modeled in software. On line 161 you will find the main function with the co-simulation testbench. Inside the testbench, there are 47 test cases taken from the WideMultTopPf_Tb.sv testbench.
int main() {
// input test vectors
const int NUM_INPUTS = 47;
...
Starting on line 316, we prepare some constants and a SmartHLS initiator
object to pass into the top-level interface. The axi_if
object can be
thought of as a FIFO with the AXI channels described in the AXI4 Protocol Primer. We
provide the FIFO depth as the argument. We must make sure that it is
deep enough to hold all inputs before writing to it.
// Prepare for AXI initiator interface reads/writes
const int NUM_READS_PER_INPUT = 16;
const int NUM_WRITES_PER_INPUT = 8;
const int WORD_SIZE = 4;
AxiInterface<ap_uint<32>, ap_uint<32>, ap_uint<4>> axi_if(NUM_INPUTS *
NUM_READS_PER_INPUT);
We will write all of the input words to be read by the initiator using
the prepare_axi_read
function, found on line 150. This function
provides an easy interface to set necessary control signals and write
the data to the initiator read data channel.
void prepare_axi_read(AxiInterface<ap_uint<32>, ap_uint<32>, ap_uint<4>> &axi_if,
ap_uint<32> input, int last = 0) {
RdDataSignals<ap_uint<32>> r_sig;
r_sig.data = input;
r_sig.resp = 0;
r_sig.last = last;
axi_if.r.write(r_sig);
}
On line 323, we use the prepare_axi_read
function to write all inputs
to the initiator read data channel, making sure to set the last signal
on the last read per transaction. We also pre-write the write response
for the accelerator for each transaction so that the accelerator can
read it after a write transaction to the interface.
for (int i = 0; i < NUM_INPUTS; i++) {
prepare_axi_read(axi_if, A[i](31, 0));
...
prepare_axi_read(axi_if, E[i](127, 96), /*last=*/1);
WrRespSignals b_sig;
axi_if.b.write(b_sig);
}
Next, we set the run field in the target memory to the number of inputs we have written and then set the base address to 0. We then run the accelerator to produce the results.
// AXI target inputs
data.run = NUM_INPUTS;
data.base_addr = 0;
// Run the top-level function that will be synthesize to hardware.
wide_mult_axi(axi_if);
Starting on line 352, we check that the addresses read from and written to are correct by reading from the read and write address channels and checking each address line up.
int mismatch_addr_cnt = 0;
ap_uint<32> addr = 0;
// Check that the read and write addresses were as expected.
for (int i = 0; i < NUM_INPUTS; ++i) {
if (addr != axi_if.ar.read().addr)
mismatch_addr_cnt++;
addr += NUM_READS_PER_INPUT * WORD_SIZE;
if (addr != axi_if.aw.read().addr)
mismatch_addr_cnt++;
addr += NUM_WRITES_PER_INPUT * WORD_SIZE;
}
Next, we check that the result data is correct by reading them from the write data channel and comparing them with the pre-generated results taken from the SystemVerilog testbench.
// Read all of write data.
int mismatch_cnt = 0;
for (int i = 0; i < NUM_INPUTS; ++i) {
ap_fixpt<256, 192> result;
result(31, 0) = axi_if.w.read().data;
...
result(255, 224) = axi_if.w.read().data;
std::cout << "A: " << A[i].raw_bits() << " B: " << B[i]
<< " C: " << C[i] << " D: " << D[i].raw_bits()
<< " E: " << E[i].raw_bits() << "\n";
std::cout << "Expected: " << expected_results[i].raw_bits()
<< ", Actual: " << result.raw_bits() << "\n";
if (result != expected_results[i]) {
mismatch_cnt++;
std::cout << "ERROR: mismatch\n";
} else {
std::cout << "Matched!\n";
}
}
We report the final results and return any errors found in the testbench for co-simulation to check.
std::cout << "Incorrect addresses: " << mismatch_addr_cnt << "\n";
std::cout << "Mismatches: " << mismatch_cnt << "\n";
if (mismatch_addr_cnt || mismatch_cnt)
std::cout << "FAIL\n";
else
std::cout << "PASS\n";
return mismatch_addr_cnt || mismatch_cnt;
Now generate the hardware for this design (). You will the same AXI Slave (target) interface generated as before, but now there is also an AXI Master (initiator) interface.
====== 1. RTL Interface ======
+-------------------------------------------------------------------------------------------+
| RTL Interface Generated by SmartHLS |
+-----------+----------------+------------------------+------------------+------------------+
| C++ Name | Interface Type | Signal Name | Signal Bit-width | Signal Direction |
+-----------+----------------+------------------------+------------------+------------------+
| | Clock & Reset | clk (positive edge) | 1 | input |
| | | reset (sync. act. high)| 1 | input |
+-----------+----------------+------------------------+------------------+------------------+
| | Control | finish | 1 | output |
| | | ready | 1 | output |
| | | start | 1 | input |
+-----------+----------------+------------------------+------------------+------------------+
| initiator | AXI Master | initiator_ar_addr | 32 | output |
| | | initiator_ar_burst | 2 | output |
| | | initiator_ar_len | 8 | output |
| | | initiator_ar_ready | 1 | input |
| | | initiator_ar_size | 3 | output |
| | | initiator_ar_valid | 1 | output |
| | | initiator_aw_addr | 32 | output |
| | | initiator_aw_burst | 2 | output |
| | | initiator_aw_len | 8 | output |
| | | initiator_aw_ready | 1 | input |
| | | initiator_aw_size | 3 | output |
| | | initiator_aw_valid | 1 | output |
| | | initiator_b_resp | 2 | input |
| | | initiator_b_resp_ready | 1 | output |
| | | initiator_b_resp_valid | 1 | input |
| | | initiator_r_data | 32 | input |
| | | initiator_r_last | 1 | input |
| | | initiator_r_ready | 1 | output |
| | | initiator_r_resp | 2 | input |
| | | initiator_r_valid | 1 | input |
| | | initiator_w_data | 32 | output |
| | | initiator_w_last | 1 | output |
| | | initiator_w_ready | 1 | input |
| | | initiator_w_strb | 4 | output |
| | | initiator_w_valid | 1 | output |
+-----------+----------------+------------------------+------------------+------------------+
| data | AXI Slave | axi_s_ar_addr | 32 | input |
| | | axi_s_ar_burst | 2 | input |
| | | axi_s_ar_len | 8 | input |
| | | axi_s_ar_ready | 1 | output |
| | | axi_s_ar_size | 3 | input |
| | | axi_s_ar_valid | 1 | input |
| | | axi_s_aw_addr | 32 | input |
| | | axi_s_aw_burst | 2 | input |
| | | axi_s_aw_len | 8 | input |
| | | axi_s_aw_ready | 1 | output |
| | | axi_s_aw_size | 3 | input |
| | | axi_s_aw_valid | 1 | input |
| | | axi_s_b_resp | 2 | output |
| | | axi_s_b_resp_ready | 1 | input |
| | | axi_s_b_resp_valid | 1 | output |
| | | axi_s_r_data | 64 | output |
| | | axi_s_r_last | 1 | output |
| | | axi_s_r_ready | 1 | input |
| | | axi_s_r_resp | 2 | output |
| | | axi_s_r_valid | 1 | output |
| | | axi_s_w_data | 64 | input |
| | | axi_s_w_last | 1 | input |
| | | axi_s_w_ready | 1 | output |
| | | axi_s_w_strb | 8 | input |
| | | axi_s_w_valid | 1 | input |
+-----------+----------------+------------------------+------------------+------------------+
Next, run the co-simulation (). You should see the following in the output:
Incorrect addresses: 0
Mismatches: 0
PASS
...
Simulation time (cycles): 1,659
SW/HW co-simulation: PASS
In this training, we target the PolarFire FPGA Video and Imaging Kit (MPF300-VIDEO-KIT). The peripherals of the board are shown in Figure 8. We will use the HDMI 1.4 TX (J2) to display output on a computer monitor and the USB-UART (J12) for bitstream programming, and communication with the Mi-V.
Figure 8: PolarFire® Video and Imaging Kit Peripherals
To program the design to the PolarFire board:
-
If you have not already, download a terminal emulator like PuTTY. We will use this to communicate with the Mi-V via UART.
-
Connect the USB cable from J12 on the PolarFire® board to your PC.
-
Connect the HDMI cable from the PolarFire Video Kit (J2) to your external Monitor.
-
Refer to DG0849 and the Video Kit schematics for jumper settings. We use the default jumper settings shipped with the board.
-
Connect the AC adapter to the board and power it on (SW4).
-
Open up FlashPro Express (FPExpress v2024.2), which you can find in the Start Menu, listed under “Microchip Libero SoC v2024.2”:
- Select Project and New Job Project.
-
Now select the job file “
Training3/VIDEO_KIT_TOP.job
” downloaded from the release assets. Alternatively, you may generate your own bitstream from the Libero project created in the prerequisites by running "Generate Bitstream", which runs Synthesis, Place and Route, and Timing (approx. 1-2 hours.) -
Enter a project location. Click OK.
-
Now the Programmer window will open. If you do not see the Programmer for the MPF300TS PolarFire® FPGA, then click Refresh/Rescan Programmers.
-
Now click the RUN button to program the FPGA.
-
After programming you should see the RUN PASSED. Now close FlashPro Express.
- Now open the Windows Device Manager menu by opening the Start Menu and then searching for Device Manager.
- In the Device Manager, look for a device type called Ports (COM & LPT) and open it. You should find a COM port corresponding to the USB connection with the PolarFire Video Kit. Note this COM port number. If there is confusion about which COM port it is, unplug then re-plug it to see which one disappears and then appears.
- Now open PuTTY, select Serial connection, enter a baud rate of 115200, and enter the same COM port you saw in Device Manager. Next click Open.
- This will open an empty PuTTY console.
-
Now double check the HDMI cable from the PolarFire Video Kit (J2) to your external Monitor as the design will block until there is a screen detected.
-
Power cycle the board. You should see a rotating image on your HDMI output. This video feed is coming from the texture mapper SmartHLS core.
- You should also see output in PuTTY with some setup messages and a line asking for “mode”. This is the wide multiply operation mode.
- Choose to run in single mode (1). The Mi-V will prompt you to enter in each input to the wide multiply as 32-bit unsigned chunks. Enter the values in hexadecimal. If the Mi-V complains that you are sending an invalid character when pressing enter, make sure that your terminal is sending CR when enter is pressed rather than LF or CR LF.
- Next, choose to run in burst mode (2) The Mi-V will automatically send some testbench values to DDR and signal to the wide multiply core to operate on them. Afterwards the Mi-V will print out the results stored to DDR by the multiply core.
In this section we will go through the reference SmartHLS implementation of the wide multiply block. The reference implementation achieves the performance requirement of 156.25 MHz and is pipelined with initiation interval equal to 1 and a latency of 7. It uses the same number of MACCs as the RTL implementation but uses more 4LUTS, and fewer DFF. Part of this extra usage is due to the longer pipeline SmartHLS generated compared to the RTL design.
To see this implementation, open the wide_mult project in SmartHLS and open the wide_mult.cpp source file.
At the top of the file, we have included the ap_fixpt
and ap_int
SmartHLS libraries. These are the SmartHLS types that we can use to
easily implement wide data types.
#include <hls/ap_fixpt.hpp>
#include <hls/ap_int.hpp>
...
On line 15, we define the wide_mult
top-level function, which will
implement our wide multiply block. From this function, we take the
arguments A-E as arguments and return the result as a return value. The
types of the inputs and output correspond to the types described in
the Design Overview. Note, the ap_fixpt
type takes the width as the first
template argument and the number of integer bits as the second
argument.
ap_fixpt<256, 192> wide_mult(ap_fixpt<128, 64> A, ap_uint<64> B, ap_int<64> C,
ap_fixpt<128, 64> D, ap_fixpt<128, 64> E) {
#pragma HLS function top
Inside the function body, on line 18, we use the function pipeline pragma to tell SmartHLS to generate a pipeline for the function body.
#pragma HLS function pipeline
On line 21 and 22, we declare the intermediate types used for the calculations. Since overflow bits must be handled, we declare the width of the intermediate types to be the sum of the widths of the two input types for multiplies and the same size as the wider input for additions. For the multiply between E and C (128x64) the result becomes 192-bits wide with 128 integer bits (64 fractional bits). For the multiply between the o intermediate result and C (192x64), the result becomes 256-bits wide with 192 integer bits (64 fractional bits).
ap_fixpt<192, 128> m, n, o;
ap_fixpt<256, 192> p, q;
Starting on line 24, we have the implementation of the wide multiply operations. This performs the operations described in the Design Overview while making sure to assign each result to the appropriately sized intermediate result to handle overflow. We return the final addition value as the result of the operation.
m = C * E;
n = m.ashr(1);
o = D + n;
p = C * o;
q = A + p;
return B + q;
As mentioned in the Helpful SmartHLS Features, SmartHLS automatically handles sign extension, padding, and shifting when operating on arbitrary precision fixed-point and arbitrary precision integers of different sizes. SmartHLS also automatically removes the padding when generating the hardware operations to prevent generating operations that are unnecessarily wide.
Also, as mentioned in the Design Overview, the original RTL uses Shift Register
blocks as delay elements to line up the inputs to the pipeline stages
where they are used. These were implemented with uSRAM FIFOs. SmartHLS
2022.3 also uses uSRAM FIFOs for pipeline registers. If you are using an
older version of SmartHLS, you can set the
USE_FIFO_FOR_PIPELINE_REG
parameter to 1 in a custom configuration file to enable this behavior.
The steps to do this are similar to setting the STRENGTH_REDUCTION
parameter as seen in the RGB2YCbCr section of the SmartHLS Training 1 document.
Go back to wide_mult.cpp. On line 32, we have a software testbench that checks that the result from the wide multiply works for the cases in the SystemVerilog testbench. This can be used to verify the design in both software and co-simulation.
int main() {
// input test vectors
const int** NUM_INPUTS = 47;
...
On line 188, the main testbench loop runs each wide multiply operation and checks to see if the results match results generated by the SystemVerilog testbench.
for (int i = 0; i < NUM_INPUTS; i++) {
ap_fixpt<256, 192> result;
result = wide_mult(A[i], B[i], C[i], D[i], E[i]);
std::cout << "A: " << A[i].raw_bits() << " B: " << B[i]
<< " C: " << C[i] << " D: " << D[i].raw_bits()
<< " E: " << E[i].raw_bits() << "\n";
std::cout << "Expected: " << expected_results[i].raw_bits()
<< ", Actual: " << result.raw_bits() << "\n";
if (result != expected_results[i]) {
mismatch_cnt++;
std::cout << "ERROR: mismatch\n";
} else {
std::cout << "Matched!\n";
}
}
We report the final results and return any errors found in the testbench for co-simulation to check.
std::cout << "Mismatches: " << mismatch_cnt << "\n";
if (mismatch_cnt)
std::cout << "FAIL\n";
else
std::cout << "PASS\n";
return mismatch_cnt;
Run software simulation by clicking the Run Software button (). SmartHLS will automatically detect saved dependency changes and compile them before running the software. You should see that the software simulation passed:
...
Mismatches: 0
PASS
Now generate the hardware
(). In the summary.hls.wide_mult.rpt file,
scroll down to Section 1: RTL Interface. Verify that the arguments A-E
have been generated as scalar interfaces with the correct widths, and
that the return_val
port has been generated as a 256-bit output.
====== 1. RTL Interface ======
+----------------------------------------------------------------------------------------------------+
| RTL Interface Generated by SmartHLS |
+----------+-----------------+---------------------------------+------------------+------------------+
| C++ Name | Interface Type | Signal Name | Signal Bit-width | Signal Direction |
+----------+-----------------+---------------------------------+------------------+------------------+
| | Clock & Reset | clk (positive edge) | 1 | input |
| | | reset (synchronous active high) | 1 | input |
+----------+-----------------+---------------------------------+------------------+------------------+
| | Control | finish | 1 | output |
| | | ready | 1 | output |
| | | return_val | 256 | output |
| | | start | 1 | input |
+----------+-----------------+---------------------------------+------------------+------------------+
| A | Scalar Argument | A | 128 | input |
+----------+-----------------+---------------------------------+------------------+------------------+
| B | Scalar Argument | B | 64 | input |
+----------+-----------------+---------------------------------+------------------+------------------+
| C | Scalar Argument | C | 64 | input |
+----------+-----------------+---------------------------------+------------------+------------------+
| D | Scalar Argument | D | 128 | input |
+----------+-----------------+---------------------------------+------------------+------------------+
| E | Scalar Argument | E | 128 | input |
+----------+-----------------+---------------------------------+------------------+------------------+
Next, scroll down to Section 2: Function and Loop Scheduling Results then scroll to the right to check the initiation interval and pipeline latency of the design. Verify that the initiation interval (II) for the circuit is 1 and that the pipeline latency is 7 cycles.
====== 2. Function and Loop Scheduling Results ======
+-------------------------------------------+
| Function: wide_mult takes 7 cycles II = 1 |
+-------------------------------------------+
Since we have a custom testbench with the same test cases as the software testbench, we will skip running co-simulation.
Now open the WideMultTopPf_Tb.sv file in SmartHLS by right clicking and selecting Open With->Text Editor. This is the same testbench as the one present in the wide_mult_template project. This testbench can also be used to verify the correctness of the hardware generated by SmartHLS. Run the custom testbench (). You should see the following output:
...
# This testbench expects a pipelined wide multiply with initiation
interval of 1 and pipeline latency of 43.
# If there are mismatches in this testbench but not in co-simulation,
check your pipeline results.
# Simulation finished! 0 mismatches.
# PASS
...
Now run synthesis (). This should take 10-15 minutes. In the summary.results.rpt file, you should find something similar to the following:
====== 2. Timing Result of HLS-generated IP Core (top-level module: wide_mult_top) ======
+--------------+---------------+-------------+-------------+----------+-------------+
| Clock Domain | Target Period | Target Fmax | Worst Slack | Period | Fmax |
+--------------+---------------+-------------+-------------+----------+-------------+
| clk | 10.000 ns | 100.000 MHz | 3.677 ns | 6.323 ns | 158.153 MHz |
+--------------+---------------+-------------+-------------+----------+-------------+
The reported Fmax is for the HLS core in isolation (from Libero's post-place-and-route timing analysis).
When the HLS core is integrated into a larger system, the system Fmax may be lower depending on the critical path of the system.
====== 3. Resource Usage of HLS-generated IP Core (top-level module: wide_mult_top) ======
+--------------------------+--------------------+--------+------------+
| Resource Type | Used | Total | Percentage |
+--------------------------+--------------------+--------+------------+
| Fabric + Interface 4LUT* | 4840 + 2880 = 7720 | 299544 | 2.58 |
| Fabric + Interface DFF* | 2381 + 2880 = 5261 | 299544 | 1.76 |
| I/O Register | 0 | 1536 | 0.00 |
| User I/O | 0 | 512 | 0.00 |
| uSRAM | 0 | 2772 | 0.00 |
| LSRAM | 0 | 952 | 0.00 |
| Math | 80 | 924 | 8.66 |
+--------------------------+--------------------+--------+------------+
The results for this design might vary quite a bit. It is normal to see somewhat higher Fmax and somewhat higher DFF usage in your synthesis run.
The Fmax for this synthesis run was 156.666 MHz, which is similar to the required 156.25 MHz. The 4LUT and DFF usage are different from the original RTL implementation. The design uses the same number of MACCs as the RTL implementation thanks to SmartHLS generating the multiplies as 128x64 and 192x64. Table 2 shows the resource usage comparison between the RTL implementation and SmartHLS.
Implementation | Fabric + Interface 4LUT | Fabric + Interface DFF | uSRAM | MACC |
---|---|---|---|---|
RTL | 1958 + 3288 (5246) | 10839 + 3288 (14127) | 34 | 80 |
SmartHLS with uSRAM | 4840 + 2880 (7720) | 2381 + 2880 (5261) | 0 | 80 |
Table 3 shows the number of lines of code required to implement this design in both RTL and in C++ using SmartHLS. As you can see the SmartHLS implementation offers much fewer lines of code allowing for much better productivity.
Implementation | Lines of Code for Core | Lines of Code for Testbench without Test Cases |
---|---|---|
RTL | 290 | 198 |
SmartHLS | 16 | 18 |
Overall, the SmartHLS implementation has comparable resource usage to the original RTL implementation, while allowing the user to design at a higher level of abstraction.
In this section we will go over the reference implementation of the AXI target interface. The Mi-V provides the A-E inputs used by the wide multiplier and sends control signals to run the accelerator. The accelerator takes the A-E inputs and writes the result back to the Mi-V through the read channels when requested by the Mi-V. This can easily be implemented in SmartHLS as an AXI target struct with the AXI target interface pragma.
Open the wide_mult_axi_target project and open the axi4_target.h source file.
The TargetLayout struct defines the data that will be sent from and to the Mi-V. You will find that the structure of the target struct is the same as the struct found in initiator_layout.txt. All elements are 32-bit unsigned integer words to match the data types used in the Mi-V SoftConsole code. In the struct, we have the run control variable used by the Mi-V to start the accelerator. We have eight words to represent the 256-bit result from the wide multiply block. We also have four words to represent each of the 128-bit A, D, and E arguments, and two words to represent the 64-bit B, and C arguments. There is an extra “padding” word at the end of the struct as SmartHLS only supports AXI target structs with a size that is a multiple of 64-bits. This is due to the generated AXI data bus being fixed to 64-bits.
struct TargetLayout {
uint32_t run;
uint32_t result0;
...
uint32_t result7;
uint32_t A0;
...
uint32_t E3;
uint32_t padding;
};
Open wide_mult_axi.cpp and go to line 17, we
declare a global variable of the above type that will serve as our AXI
target channel. We use the interface pragma with the axi_slave
type to
tell SmartHLS to generate this global variable as an AXI4 target (slave)
interface. The concurrent access flag specifies that the AXI initiator
can access the target values while the wide multiply core is running.
The struct does not need to be declared volatile as SmartHLS will handle
this struct differently compared to a normal struct variable due to the
pragma.
// global variable for AXI4-Lite target
#pragma HLS interface variable(data) type(axi_slave) concurrent_access(true)
TargetLayout data;
SmartHLS will implement this interface by using the address provided in the write and read address channels to write and read to internal RAMs representing the elements of the struct.
In the wide_mult
function body, starting on line 30, we check if the
run control signal has been set by the Mi-V and then read the inputs and
assign them to the corresponding arbitrary precision variable slice. We
perform the same calculation as before, then write each slice of the
results to the AXI target interface struct. We then set the run control
signal to 0 to signal to the Mi-V that the calculation has finished. The
Mi-V will poll run until it becomes 0 and then send a read request to
read the computation results from the SmartHLS target.
if (data.run) {
A(31, 0) = data.A0;
...
E(127, 96) = data.E3;
m = C * E;
n = m.ashr(1);
o = D + n;
p = C * o;
q = A + p;
r = B + q;
data.result0 = r(31, 0);
...
data.result7 = r(255, 224);
data.run = 0;
}
Go to wide_mult_axi.cpp line 70. we have a software testbench that checks that the result from the wide multiply works for the cases in the SystemVerilog testbench. This can be used to verify the design in both software and co-simulation.
int main() {
// input test vectors
const int NUM_INPUTS = 47;
...
On line 225, the main testbench loop runs each wide multiply operation and checks to see if the results match results generated by the SystemVerilog testbench. This time the testbench writes the input data to and reads the result from the AXI4 TargetLayout struct.
unsigned mismatch_cnt = 0;
for (int i = 0; i < NUM_INPUTS; i++) {
data.A0 = A[i](31, 0);
...
data.E3 = E[i](127, 96);
data.run = 1;
wide_mult();
ap_fixpt<256, 192> result;
result(31, 0) = data.result0;
...
result(255, 224) = data.result7;
std::cout << "A: " << A[i].raw_bits() << " B: " << B[i]
<< " C: " << C[i] << " D: " << D[i].raw_bits()
<< " E: " << E[i].raw_bits() << "\n";
std::cout << "Expected: " << expected_results[i].raw_bits()
<< ", Actual: " << result.raw_bits() << "\n";
if (result != expected_results[i]) {
mismatch_cnt++;
std::cout << "ERROR: mismatch\n";
} else {
std::cout << "Matched!\n";
}
}
We report the final results and return any errors found in the testbench for co-simulation to check.
std::cout << "Mismatches: " << mismatch_cnt << "\n";
if (mismatch_cnt)
std::cout << "FAIL\n";
else
std::cout << "PASS\n";
return mismatch_cnt;
Next, run the co-simulation (). You should see the following in the output:
Mismatches: 0
PASS
...
Simulation time (cycles): 2,585
SW/HW co-simulation: PASS
Compile to hardware (). There is a new report that was generated that we have not seen before. This axi_slave_memory_map.hls.rpt file holds the memory mapped addresses for the generated AXI target struct. These addresses can be used by the Mi-V initiator to communicate with the generated AXI target.
From the Mi-V, we need to correctly setup the correct base address in the Mi-V IP interface configuration and any AXI Interconnect IPs used to connect the Mi-V to the SmartHLS target. We can write and read to those memory mapped addresses to communicate with the target. More information on the processor code and AXI Interconnect can be found in Appendix A.
Now open the summary.hls.wide_mult.rpt file and scroll down to Section 1: RTL Interface. Check that an interface of type AXI Slave (target) has been generated. This is the AXI4 target interface generated for our data global variable.
====== 1. RTL Interface ======
+--------------------------------------------------------------------------------------+
| RTL Interface Generated by SmartHLS |
+----------+----------------+--------------------+------------------+------------------+
| C++ Name | Interface Type | Signal Name | Signal Bit-width | Signal Direction |
+----------+----------------+--------------------+------------------+------------------+
| | Clock & Reset | clk (pos. edge) | 1 | input |
| | | reset (sync. high) | 1 | input |
+----------+----------------+--------------------+------------------+------------------+
| | Control | finish | 1 | output |
| | | ready | 1 | output |
| | | start | 1 | input |
+----------+----------------+--------------------+------------------+------------------+
| data | AXI Slave | axi_s_ar_addr | 32 | input |
| | | axi_s_ar_burst | 2 | input |
| | | axi_s_ar_len | 8 | input |
| | | axi_s_ar_ready | 1 | output |
| | | axi_s_ar_size | 3 | input |
| | | axi_s_ar_valid | 1 | input |
| | | axi_s_aw_addr | 32 | input |
| | | axi_s_aw_burst | 2 | input |
| | | axi_s_aw_len | 8 | input |
| | | axi_s_aw_ready | 1 | output |
| | | axi_s_aw_size | 3 | input |
| | | axi_s_aw_valid | 1 | input |
| | | axi_s_b_resp | 2 | output |
| | | axi_s_b_resp_ready | 1 | input |
| | | axi_s_b_resp_valid | 1 | output |
| | | axi_s_r_data | 64 | output |
| | | axi_s_r_last | 1 | output |
| | | axi_s_r_ready | 1 | input |
| | | axi_s_r_resp | 2 | output |
| | | axi_s_r_valid | 1 | output |
| | | axi_s_w_data | 64 | input |
| | | axi_s_w_last | 1 | input |
| | | axi_s_w_ready | 1 | output |
| | | axi_s_w_strb | 8 | input |
| | | axi_s_w_valid | 1 | input |
+----------+----------------+--------------------+------------------+------------------+
Figure 99, shows the SmartDesign IP component that contains the SmartHLS-generated wide multiply block.
Figure 9: Block Diagram of the SmartHLS-generated wide multiply block
To integrate the PolarFire® Video Kit design in Libero SoC 2024.2:
- Launch Libero SoC 2024.2 and open the SmartHLS_Training3 project by
navigating to and clicking
Training3/Libero/Libero_training3/Libero_training3.prjx
. - Navigate to the Design Hierarchy and search for “
wide_mult
”. Right click thewide_mult_axi_top
design component and select Unlink. We want to avoid any duplicate blocks when importing the new wide multiply design from SmartHLS.
- Now clear the search, then click the plus next to the TOP
SmartDesign file and then double click
LEGUP_PROCESSING
to open it in the SmartDesign Canvas.
- On the top toolbar, click Project->Execute Script... and run the
create_hdl_plus.tcl
file from thewide_mult_axi/hls_output/scripts/libero
SmartHLS project directory. SmartDesign will open a report window when it finishes. Make sure the script executed successfully and then close the report window.
- Next find the
wide_mult_axi_top
block inLEGUP_PROCESSING
and right click and select Replace Component. Select the newly importedwide_mult_axi_top
to replace the SmartDesign block without having to reconnect any wires.
- Click the “Generate Component” () button in
the SmartDesign toolbar for
LEGUP_PROCESSING
. - The
wide_mult_axi_top
SmartHLS block has now been integrated and the project is ready for synthesis, place, and route.
In order to communicate with the SmartHLS module through AXI4, the Mi-V must be configured properly to have an AXI4 initiator interface generated for a certain address range. The Mi-V can then write to this address range in order to interact with the module through the AXI4 initiator interface.
Note again, the AXI4 protocols define a master and a slave. In this training, we will refer to them as the AXI4 initiator and the AXI4 target. However, the diagrams, tools, and online references used for this training will still refer to them as AXI4 master and AXI4 slave. Whenever you see these terms in SmartDesign or configurators, know that we will refer to master as initiator and slave as target.
To see how to configure the Mi-V to have an AXI4 initiator interface, open the Libero project. Open the Design Hierarchy tab and expand the TOP SmartDesign canvas, then double click the CPU_SYS canvas to open it. This canvas has the Mi-V core.
In the opened SmartDesign canvas, double click
on the MIV_R32_C0_0
core to bring up the configuration menu.
In the Memory Map tab of the configurator, scroll down to the third entry where the AXI Master Address configuration is. This range defines the range of addresses in the Mi-V to map the AXI initiator interface to. Leave the address range as default.
If you right click on the AXI4_MSTR
bus and
select Show/Hide BIF Pins, you will find that the read and write data
bus has a width of 32-bits. If you remember from before, the AXI4 target
interface generated by SmartHLS has a data bus width of 64-bits. In
order to connect the Mi-V initiator with the SmartHLS target interface,
we need to bridge these different data bus widths.
Now close the CPU_SYS
canvas and open the TOP
canvas. Find the CLOCK_RESET_0
block.
If you follow the CLK
outputs, you will find
that the Mi-V runs on the 50MHz clock (CLK50_o
) while the SmartHLS
generated accelerators run on the 100MHz clock (CLK100_o
). In order for
the Mi-V to communicate with the SmartHLS module through AXI4, these two
clock domains must also be bridged.
The last problem we need to consider when connecting the Mi-V initiator is how many targets it will need to control. In this design, the Mi-V initiator has three AXI4 targets, the texture mapper, the wide multiply, and the DDR controller. The same AXI4 initiator interface cannot be used to control all three targets at the same time. We need a way to differentiate which target we want to send commands to in any given write and read request.
Luckily, these three problems can easily be solved by using an AXI Interconnect. This core allows multiple initiators to map to multiple targets, with different address ranges mapping to different targets. The AXI Interconnect can also handle different clocks for each initiator and target connected to it.
Close the TOP canvas and open the
LEGUP_PROCESSING
canvas and find the COREAXI4INTERCONNECT_C0_0
block.
Double click it to open the configurator.
In the Configuration tab of the configurator, you will be able to find settings to control the number of initiators and targets connected to this AXI Interconnect. You can also modify some other settings such as address width, but for this design those do not need to be modified from default. You can see that this AXI Interconnect is configured to connect one initiator to three targets.
In the Master Configuration tab, we can choose the protocol type and data bus width of the initiator interface. The Mi-V initiator interface is a AXI4 interface with data width 32. You may also notice that the M0 Clock Domain Crossing checkbox is checked. This will generate a clock input that will be used to provide the clock used by the initiator. The clock used by the targets is provided through the main clock input on the core.
In the Slave Configuration tab, we have three targets configured. Note, the first target interface is connected to the texture mapper SmartHLS core. The target type generated is AXI4-Lite to match the AXI4-Lite with burst enabled interface generated by SmartHLS. When connected to an AXI4-Lite interface, the burst option will not be used. Optionally, the interface type may be changed to AXI4 in the configuration to enable burst. The data width is set to 64-bits, which is the generated data width for the SmartHLS target interface. We also assign an address range of 0x60000000 to 0x60ffffff out of the original 0x60000000 to 0x6fffffff address range to map to the texture mapper module. Writing to and reading from this range from the Mi-V will cause the AXI Interconnect to send the requests only to the first target interface. The second target interface is connected to the wide multiply module and is configured the same way as the texture mapper. The wide multiply module is given the address range 0x61000000 to 0x61ffffff. The last target interface connects to a second AXI Interconnect which then connects to DDR and is given the remaining address range.
In the Crossbar Configuration, we can optionally change which initiators have read and write permissions to which target. Since we have one initiator that should be able to communicate with all targets, all checkboxes are checked.
The Slave2 output of COREAXI4INTERCONNECT_C0_0
is connected to the
first initiator input of a second AXI Interconnect. The wide multiply
initiator is connected to the second initiator input. This AXI
Interconnect takes two initiator interfaces and arbitrates its access to
a single target. Since the DDR is on a different clock domain than the
two initiators, while the initiators are on the same clock domain, a
single target clock input is used to provide the clock that is used by
the target while the clock for the initiators is provided as the main
clock input.
To connect an AXI target interface to an AXI initiator interface, as in
the case where we want to connect the output from one interconnect to a
second interconnect, the AXITOAXICONNECT
core can be used. This converts
an AXI target interface to an AXI initiator interface with no
modification.
With the help of AXI Interconnects, the AXI initiators were able to be connected to their AXI targets at set address ranges.
We have talked about designing the interfaces to match with the code running on the Mi-V soft processor when designing the wide multiply AXI-target interface. Now we will see how to write to and read from the target using the Mi-V processor. The following Mi-V code corresponds to the wide multiply implementation that has both single and burst mode operation.
In the wide_mult_axi SmartHLS project, open the sc_main_c file. This file is a copied version of the SoftConsole code running on the Mi-V. The name has been changed from main.c so that SmartHLS does not pick it up as an HLS source and try to compile it.
Near the top of the source file, on line 59 and 96, we declare some addresses. The addresses match the base addresses of the ranges we have seen in the Mi-V configurator for the AXI4 initiator and the AXI Interconnect configurators in the previous section.
// SmartHLS Wide Multiplier AXI-Slave Base Address
#define SHLS_WIDE_MULT_BASE_ADDR 0x61000000UL
...
// DDR AXI-Slave Base Address
#define DDR_BASE_ADDR 0x62000000UL
Starting on line 14 and 62, we have the structs used line up with the address offsets from the generated SmartHLS AXI target interface report. The address above will be cast to pointers to these structs and the struct pointers will be used to write to and read from the addresses. Note, the wide multiply struct matches the struct declared in the SmartHLS core, while the DDR struct matches the memory format expected by the wide multiply core.
// SmartHLS Wide Multiplier AXI Target Layout
struct wide_mult {
...
};
...
// SmartHLS Wide Multiplier DDR Layout
struct wide_mult_ddr {
...
};
In the main function on line 535, we run one of two functions,
run_single_multiply
and run_burst_multiply
, depending on user input.
// Run Wide Multiplier loop
while (1) {
uint32_t mode =
get_user_input("Enter mode (1 for single, 2 for burst): ", 41);
if (mode == 1) {
run_single_multiply();
} else {
run_burst_multiply();
}
}
If the user enters 1, the Mi-V will run the multiply core in single mode
using the run_single_multiply
function found on line 234. This
function takes user input as the inputs A-E and sends them to the
accelerator. To write to the accelerator, the Mi-V casts the base
address we defined into the appropriate struct format and uses this
format to write and read from the addresses that line up with addresses
in the AXI target interface in the SmartHLS core. For burst mode, the
processor will also write to and read from addresses corresponding to
the DDR memory. Note, the pointers are cast as volatile to prevent the
SoftConsole compiler from optimizating away these reads and writes. The
Mi-V then asserts the run signal and waits until the accelerator
de-asserts it, signally the computing is done. The Mi-V then reads from
the memory to issue read requests and get the results from the
accelerator.
void run_single_multiply() {
struct wide_mult wm;
...
print("Sending input to SmartHLS accelerator\r\n");
volatile struct wide_mult *wm_accel_addr =
(volatile struct wide_mult *) SHLS_WIDE_MULT_BASE_ADDR;
wm_accel_addr->A0 = wm.A0;
...
wm_accel_addr->E3 = wm.E3;
print("Starting SmartHLS accelerator\r\n");
wm_accel_addr->run = 1;
print("Waiting for SmartHLS accelerator to finish\r\n");
while (wm_accel_addr->run);
print("Reading result from SmartHLS accelerator:\r\n");
wm.result0 = wm_accel_addr->result0;
...
wm.result7 = wm_accel_addr->result7;
...
}
If the user enters 2, the Mi-V will run the multiply core in burst mode
using the run_burst_multiply
function. This function writes five
testbench cases into DDR and allows the accelerator to process all five
inputs before reading and checking the results from DDR. Communication
with the accelerator works the same way as in single mode but now data
is transferred between the accelerator and the Mi-V through the DDR.
void run_burst_multiply() {
// 5 test inputs
#define NUM_BURST 5
...
print("Writing inputs to DDR\r\n");
volatile struct wide_mult_ddr *ddr_addr =
(volatile struct wide_mult_ddr *) DDR_BASE_ADDR;
for (uint32_t i = 0; i < NUM_BURST; i++) {
ddr_addr->A0 = A0[i];
...
ddr_addr->E3 = E3[i];
ddr_addr->result0 = i;
...
ddr_addr->result7 = i;
ddr_addr++;
}
Then we can start the SmartHLS accelerator by giving it the base address of the DDR to start operating on and writing the number of operations to processes to the run.
print("Starting SmartHLS accelerator\r\n");
volatile struct wide_mult *wm_accel_addr =
(volatile struct wide_mult *) SHLS_WIDE_MULT_BASE_ADDR;
wm_accel_addr->base_addr = DDR_BASE_ADDR;
wm_accel_addr->run = NUM_BURST;
Then we poll on the run address until this becomes 0, indicating the SmartHLS accelerator is done.
print("Waiting for SmartHLS accelerator to finish\r\n");
while (wm_accel_addr->run);
Then we read the SmartHLS accelerator results from DDR memory and check against the expected results.
print("Reading results from DDR\r\n");
ddr_addr = (volatile struct wide_mult_ddr *) DDR_BASE_ADDR;
const int BUF_LEN = 200;
char buf[BUF_LEN];
for (uint32_t i = 0; i < NUM_BURST; i++) {
snprintf(buf, BUF_LEN, "Inputs (hex) from DDR for run %d:\r\n"
"A: %x %x %x %x\r\n"
"B: %x %x\r\n"
"C: %x %x\r\n"
"D: %x %x %x %x\r\n"
"E: %x %x %x %x\r\n", i,
ddr_addr->A3, ddr_addr->A2, ddr_addr->A1, ddr_addr->A0,
ddr_addr->B1, ddr_addr->B0,
ddr_addr->C1, ddr_addr->C0,
ddr_addr->D3, ddr_addr->D2, ddr_addr->D1, ddr_addr->D0,
ddr_addr->E3, ddr_addr->E2, ddr_addr->E1, ddr_addr->E0);
print(buf);
snprintf(buf, BUF_LEN,"Result (hex) from DDR for run %d:\r\n"
...
snprintf(buf, BUF_LEN,"Expected result (hex) for run %d:\r\n"\
...
if (ddr_addr->result0 != result0[i]) {
snprintf(buf, BUF_LEN,"Mismatched result (hex) for result %d run %d:\r\n"
"Expected: %x, Got: %x\r\n", 7, i,
result7[i], ddr_addr->result7);
print(buf);
}
...
print("\r\n");
ddr_addr++;
}
}
As shown in Figure 7, the PolarFire® design also contains another SmartHLS hardware block called the Texture Mapper. The Texture Mapper SmartHLS project is based on a Rotozoom demo design created by one of our FAEs. Rotozoom stands for rotation and zoom, and the design rotates and zooms in and out on a 512x512 greyscale image and outputs to the monitor over HDMI. After programming the design onto the PolarFire Video kit in Section 'Programming and Running the Design on the PolarFire® Video Kit', you will see an output on your monitor like in Figure 10.
Figure 10: Monitor output of Text Mapper SmartHLS hardware block.
The Rotozoom code is based on the algorithm description here:
https://www.flipcode.com/archives/The_Art_of_Demomaking-Issue_10_Roto-Zooming.shtml
The Mi-V soft processor performs rotation and scaling calculations and passes coordinate and delta values to the Texture Mapper SmartHLS core as shown in Figure 11.
Figure 11: Breakdown of computation between the Mi-V processor and
SmartHLS core.
In SmartHLS, open the axi4_target.h source file in the project called texture_mapper.
The AXI target interface memory-map layout can be found here. These AXI target control status registers hold the inputs sent to the SmartHLS by the Mi-V soft processor. The AX, AY and BX, BY values are corners of the rotated/scaled texture image. The DX1DY, DY1DY, DX2DY, and DY2DY are delta values used during the interpolation in the SmartHLS core.
struct TargetLayout {
//uint64 texture_frame[texture_size*texture_size/8];
uint32 AX;
// Offset 0x00040000 (+ 512*512 bytes)
uint32 AY;
// Offset 0x00040004
uint32 BX;
// Offset 0x00040008
uint32 BY;
// Offset 0x0004000C
int32 DX1DY;
// Offset 0x00040010
int32 DY1DY;
// Offset 0x00040014
int32 DX2DY;
// Offset 0x00040018
int32 DY2DY;
// Offset 0x0004001C
// uint32 padding;
// 8-byte (64-bit) data bus alignment
};
The SmartHLS core receives a new set of AXI4 target input values for every single line of the output image. The SmartHLS core will calculate the texture value for all the output pixels and output them to a FIFO interface to the monitor.
If you open texture_mapper.cpp, you can find the definition of the gv global variable on line 32. This AXI4 target struct will be accessible by the Mi-V processor over the AXI4 target interface.
#pragma HLS interface variable(gv) type(axi_slave) concurrent_access(true)
TargetLayout gv;
On line 35, we store the texture frame, which is a 512x512 grayscale Lena image, in a block RAM in the SmartHLS core. This memory is declared in C++ by the following line:
volatile uint64 texture_frame[texture_size * texture_size / 8];
In the form of a global array, the texture frame memory will be automatically initialized to all zero in C++. Therefore, we must mark the array as volatile to prevent SmartHLS from optimizing away the computation. If you are using a version of SmartHLS older than 2024.2, you should expect to see the ‘printWarningMessageForGlobalArrayReset’ warning message about texture_frame when running Compile Software to Hardware (), and it’s safe to ignore. More detailed discussion about this warning can be found in Training 2.
You may have also noticed the set_parameter READONLY_RAM_TO_ROM 0
constraint set in config.tcl
. (The READONLY_RAM_TO_ROM
constraint was added in SmartHLS 2024.2, meaning if you are using an older version of SmartHLS, you may need to comment out that line.) Since we will use Libero to initialize the RAM instead of SmartHLS, from SmartHLS's point of view, texture_mapper
is a read-only memory. SmartHLS will turn read-only RAMs into ROMs by default (e.g. READONLY_RAM_TO_ROM
is 1.) We need to tell SmartHLS not to do this, since if this memory is implemented as a ROM, the synthesis tool may think the content inside the memory is compile time static. It may then decide to absorb the constant values into the logic and optimize the entire ROM away, meaning we can't flash in the memory content (Lena.)
Then we must specify the RAM initialization in Libero by going to
Configure Design Initialization Data and Memories -> Fabric RAMs. As
shown in Figure 12, we specified the memory initialization hex file of
the texture_frame RAM to the relative path:
“src/cfg_and_mem_files/lena_8Bit_Greyscale_512x512.hex
”.
Figure 12: Manual memory initialization of a SmartHLS-generated RAM
using Libero
The top-level function is texture_mapper, which can be found on line 70.
void texture_mapper(uint8 run_loop, uint8 &run_done,
FIFO<uint64> &output_fifo) {
#pragma HLS function top
Starting on line 101, the top-level function reads the AXI target inputs from the Mi-V processor and contains a pipelined loop to calculate the output pixels (8 at a time) for the current output line.
#pragma HLS loop pipeline
for (n = 0; n < image_width / 8; n++) {
// calculate texture coordinates of 8 pixels
p0 = get_texture_pixel(cx(31, 16), cy(31, 16));
…
// concatenate 8 pixels and place result in output FIFO
output_fifo.write((p0, p1, p2, p3, p4, p5, p6, p7));
}
At the end of the top-level function, we write a 1 to the run_done
output to indicate that the current output line has been finished:
run_done = 0x01; // processing phase completed, one line processed
This run_done
output clears a register external the texture mapper,
which then triggers an interrupt handler on the Mi-V to run the
processor side code.
We can perform a rotation of a x, y point around the origin with the following equation:
x' = x * cos( angle ) - y * sin( angle )
y' = y * cos( angle ) + x * sin( angle )
Inside the SoftConsole code running on the Mi-V soft processor, we
perform the rotation inside the rotate_points
function when an
interrupt is triggered. You can find this code on line 594 in the source
file sc_main_c found in the wide_mult_axi project.
void rotate_points(void)
{
…
int A_x_rot = (-scaled_vect1*g_cos_table[g_angle] -
scaled_vect2*g_sin_table[g_angle])>>15;
int A_y_rot = (-scaled_vect1*g_sin_table[g_angle] +
scaled_vect2*g_cos_table[g_angle])>>15;
Each time the rotate_points
function is called the g_angle
increments
by 1 until wrapping around at 360 degrees. The scaling factors
(scaled_vect2
, scaled_vect1
) perform the zooming in/out, and are
incremented each time the function is called up to a maximum and then
decremented back down.
The memory mapped addresses of the SmartHLS Texture Mapper AXI target interface are found on line 564 as a series of defines.
// SmartHLS Texture Mapper AXI Target Addresses
#define reg_AX 0x60040000UL
#define reg_AY 0x60040004UL
#define reg_BX 0x60040008UL
#define reg_BY 0x6004000CUL
#define reg_DX1DY 0x60040010UL
#define reg_DY1DY 0x60040014UL
#define reg_DX2DY 0x60040018UL
#define reg_DY2DY 0x6004001CUL
At the end of the rotate_points
function on line 629, we write the
updated inputs to the SmartHLS core using memory-mapped writes by
casting each address into a volatile pointer of the correct type and
then writing to it.
// update registers
*((uint32_t volatile *) reg_AX) = AX<<16;
*((uint32_t volatile *) reg_AY) = AY<<16;
*((uint32_t volatile *) reg_BX) = BX<<16;
*((uint32_t volatile *) reg_BY) = BY<<16;
*((int32_t volatile *) reg_DX1DY) = (((int32_t)CX-(int32_t)AX)<<16)/y_size;
*((int32_t volatile *) reg_DY1DY) = (((int32_t)CY-(int32_t)AY)<<16)/y_size;
*((int32_t volatile *) reg_DX2DY) = (((int32_t)DX-(int32_t)BX)<<16)/y_size;
*((int32_t volatile *) reg_DY2DY) = (((int32_t)DY-(int32_t)BY)<<16)/y_size;
If you make changes to the software for the MiV, follow these steps to generate a new .hex file:
- Open SoftConsole
- Open the
RV32_simple_gpio
project underTraining3/Libero/softconsole/
- Build the project
You should see this output:
Then, to integrate into your Libero project:
-
Go back to the Libero project, and click “Generate FPGA Array Data” if you haven’t. It will take 1-2h to finish.
-
After it is done, right click the Design and Memory Initialization window below it and select the “Fabric RAMs” tab.
- Right click
CPU_SYS_0/MIV_RAM_64K_0
(it should be the first RAM listed) and import the new .hex file in Libero.
- Generate Design Initialization Data and run the remaining steps to program the bitstream.