The graph pop up function for the "deprecated" service status page is not working correctly. The graph is not being displayed if you hover over the icon.
E.g.:
It seems like this is caused by the changes in the file /usr/share/centreon/www/include/monitoring/status/Services/xsl/service.xsl in line 300-303 and 345-347.
If you replace the file with an older file (Centreon 21.10), everything works fine.
Steps to Reproduce
Please describe precisely the steps to reproduce the encountered issue.
Login as usual
Go to profile settings
Enable "Use deprecated pages" and save
Go to "Status Details" -> "Services"
Hover with your mouse over any graph
The text was updated successfully, but these errors were encountered:
Description
The graph pop up function for the "deprecated" service status page is not working correctly. The graph is not being displayed if you hover over the icon.
E.g.:
It seems like this is caused by the changes in the file /usr/share/centreon/www/include/monitoring/status/Services/xsl/service.xsl in line 300-303 and 345-347.
If you replace the file with an older file (Centreon 21.10), everything works fine.
Steps to Reproduce
Please describe precisely the steps to reproduce the encountered issue.