diff --git a/config/images/thermofloor/heatitzm.png b/config/images/thermofloor/heatitzm.png
new file mode 100644
index 0000000000..40efc5da7d
Binary files /dev/null and b/config/images/thermofloor/heatitzm.png differ
diff --git a/config/manufacturer_specific.xml b/config/manufacturer_specific.xml
index c3a7576cb1..b9b63af1aa 100644
--- a/config/manufacturer_specific.xml
+++ b/config/manufacturer_specific.xml
@@ -1,5 +1,5 @@
-
+
@@ -1771,6 +1771,7 @@
+
@@ -2094,4 +2095,4 @@
-
\ No newline at end of file
+
diff --git a/config/thermofloor/heatitzm.xml b/config/thermofloor/heatitzm.xml
new file mode 100644
index 0000000000..a249dc9bf2
--- /dev/null
+++ b/config/thermofloor/heatitzm.xml
@@ -0,0 +1,95 @@
+
+
+ Heatit ZM Single Relay 16A
+ Heatit ZM Single Relay is a high power relay for in-wall installations.
+ The relay allows you to control connected devices either through your Z-Wave network or via a wired switch. The module is equipped with a 16A relay and has a scene controller functionality.
+
+ The device can withstand a load of max 16A /3600W at 230VAC.
+
+ The Heatit ZM Single Relay has a power metering feature that allows you to monitor the power consumption of your connected devices.
+ http://www.openzwave.com/device-database/019B:3500:0004
+ https://products.z-wavealliance.org/products/4062/
+ images/thermofloor/heatitzm.png
+ ZM Single Relay 16A
+ Tripple Click the button
+ CEPT (Europe)
+ Tripple Click the button
+ https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/4062/Manual_Heatit%20ZM%20Single%20Relay%2016A_Ver%202020-A_ENG.pdf
+ This device allows reset without any involvement of a Z-Wave controller.
+
+ Initial version
+ Multiline help texts revised
+
+
+
+
+ Ensures that the device does not draw more current than rated. Immunity for power consumption peaks
+
+
+
+ Decide how the device should react when the overload/overheating features has turned relay OFF:
+ 0 - Disabled and will not retry. User needs to manually turn on afterwards. If temperature overload is on, device will not turn on until device has cooled down
+ >= 1 - After power shut down (param 1) device will try to turn back ON after delay specified here. (Time in minutes)
+
+
+
+ Momentary or toggle switch
+
+
+
+
+ S1 button operation
+
+
+
+
+ Decides if/what scene controller notifications the device sends to gateway
+
+
+
+
+
+
+
+ Relay power level after power is restored from power-outage.
+ When device is from factory/factory reset the first state of the device should be OFF
+
+
+
+
+
+
+
+ 0 for auto off disabled (default)
+ 1-86400 for auto-off timeout in seconds
+
+
+
+
+ 0 for auto on disabled (default)
+ 1-86400 for auto-on timeout in seconds
+
+
+
+ Decides if the relay output should be inverted
+
+
+
+
+ Time interval between consecutive meter reports. Meter reports can also be sent as a result of polling
+
+
+ Meter report delta value
+
+
+
+
+
+
+
+
+
+
+
+
+