Skip to content

Commit

Permalink
added 12V fuse. added ground planes to PCB and did nortons analysis o…
Browse files Browse the repository at this point in the history
…n critical ground currents. neilh10/SensorModbusMaster#1
  • Loading branch information
neilh20.gitk authored and neilh20.gitk committed Feb 5, 2021
1 parent f61d94b commit 1775468
Show file tree
Hide file tree
Showing 3 changed files with 8 additions and 3 deletions.
11 changes: 8 additions & 3 deletions knh002-MayflyWingShield/README.md
Original file line number Diff line number Diff line change
Expand Up @@ -8,13 +8,18 @@ https://oshpark.com/shared_projects/ffQNVmrp

This Mayfly wingboard interface supports
- RS485 on up to three physical connectors.
- new feature - local 120ohm termination 2mm jack. The installer can simply activate the RS485 120ohm termination resistor if needed.
RS485 physical line interface designed for long lines if required, one remote 120ohms, and a local 120ohms termination resistor.
- new feature - local 120ohm termination 2mm jack. The installer can activate the RS485 120ohm termination resistor if needed.
This RS485 physical line interface designed for long lines if required, one remote 120ohms, and a local 120ohms termination resistor.
- new feature - 12V output has 100mA resetable fuse. Trips at 250mA, but will hold 100mA. If output wire is s/c will protect battery/processor reliability.
- new feature - TTL lines have power safe data lines.
Powering routing that allows connection directly to the LiIon battery. This faciliates a more efficient +12V generation and greater power resilency.
- new feature Powering routing that allows connection directly to the LiIon battery. This faciliates a more efficient +12V generation and greater power resilency.
- new feature - power can be taken directly from the LiIon battery (a build option)
- a dual led shows RED flashes for transmit to RS485 instrument, Green flashes from RS485 instrumnent (response)
- new advanced feature - fuel gauge LTC2942 ( build option )

Changes from the old Mayfly RS485 wingboard
a) doesn't use the unmanaged hybrid. These hybrids where of unspecified quality, and often didn't work.

Background (from original Mayfly Wingboard)

The [Modbus RTU](https://en.wikipedia.org/wiki/Modbus) *logical* communication protocol is typically transmitted using the *physical* [RS-485](https://en.wikipedia.org/wiki/RS-485) serial communication signaling standard.