Skip to content

Roadmap

mihtjel edited this page Oct 2, 2019 · 34 revisions

Features planned

  • Fine-tuning markers using arrow keys
  • Readout of reference data for markers
  • Statistical analysis of multiple readings
  • Customizable scaling of charts (mouse control)
  • Unwrap option for phase chart, to go beyond +/- 180
  • A Beginner's Guide to the app
  • Complex impedance divided by omega ( to evaluate µ'r and µ''r on unknow ferrite material)
  • Automatic scaling of Polar Chart
  • Alternate interleaved multi-sweeping
  • Live, interleaved sweeps
  • Admittance, Conductance/Susceptance readouts for markers
  • Complete dark mode skin
  • Linear/logarithmic frequency display in graphs
  • Set reference level for S21, as a "light" calibration.

0.1.0

  • Stability and code quality improvements
  • Phase charts are now zoomable like the others
  • Compensate calibration for the length of the through adaptor
  • Compensate calibration for inductance of the load standard
  • Savable calibration standard sets
  • Reworked calibration saves, and saved calibrations can now include notes
  • Better Touchstone support (RFSim99 should work now)
  • Saving of screenshots of charts from the right click menu

0.0.12

  • Customizable scaling of charts (first version)
  • Ensures X=0 is visible in R+jX graphs where relevant
  • Rescan button for serial ports
  • Display ham bands (or other bands)
  • Calibration assistant

0.0.11

  • Averaging of multiple readings
  • Truncated mean averaging
  • Complex impedance display curve ( R+jX : Two curves)
  • Small screen improvements: Should fit on 1366x768
  • Bugfixes

0.0.10

  • Customizable background/foreground colours
  • Adjustable font size
  • Loading of Magnitude-Angle Touchstone files
  • Debug logging (-d to enable, and/or -D to log to a file)
  • TDR readout in feet and inches
  • More settings are saved to the settings file
  • Bugfixes

0.0.9

  • Mouse-control for markers
  • New layout for marker data
  • Quality factor display curves (X / R) improved
  • Impedance display automatic precision adjustment
  • Center and span controls
  • Parallel equivalent R & L/C
  • Support for high-resolution monitors
  • TDR window, including a graph of TDR response

0.0.8

  • Saving of settings
  • Markers responsible for displaying themselves
  • Markers show the actual data point frequency
  • More cable types for TDR
  • Live sweeps
  • Quality factor display curves (X / R) (First version)

0.0.7:

  • Dark mode for nighttime analysis
  • An option for lines between points
  • Loading other types of Touchstone files (kHz, MHz and GHz supported)
  • Mouse-control for markers (Smith chart and polar chart)
  • Calibration using imperfect standards
Clone this wiki locally